Set up the ADS41xxEVM according the following diagram.
Two signal generators are used and externally locked through the 10-MHz reference. Furthermore, bandpass filters on clock and data input are used to minimize spurs and noise created by the signal generators. Depending on filter attenuation, the clock generator amplitude must be set to 10-13 dBm.
USB connection of the PC to ADS41xxEVM as well as
TSW1400 must be established and if necessary the USB drivers installed
accordingly (see Section 3.2).
The ADS41xx EVM requires a 3.3V power supply and the TSW1400 a 5V supply.
If Serial mode (SPI) is used, ensure that jumpers are set for SPI mode (SCLK, SDATA, SEN).