BIT NO. | FIELD | TYPE | RESET | DESCRIPTION |
---|---|---|---|---|
[7] | RSRVD | - | - | Reserved. |
[6] | CLKIN0_PLL1_INV | RW | 1 | Inverts CLKIN0_PLL1_RDIV.
0=Noninverted 1=Inverted |
[5] | CLKIN0_LOS_FRQ_DBL_EN | RW | 0 | CLKIN0 Loss of Source Frequency Doubler Enable. |
[4] | CLKIN0_EN | RW | 0 | CLKIN0 Input Stage Enable. (not clk buffer). |
[3] | CLKIN0_SE_MODE | RW | 1 | CLKIN0 Signal Mode.
CLKIN0_SE_MODE– Signal Mode Selection 0– Differential 1– Single-ended |
[2:0] | CLKIN0_PRIO[2:0] | RW | 0x3 | CLKIN0 Priority.