over operating free-air temperature range (unless otherwise noted)(1)(2)(3)(4)
PARAMETER |
TEST CONDITIONS |
MIN |
TYP |
MAX |
UNIT |
IA |
Analog supply current |
|
–6 |
|
6 |
mA |
ITC |
Track and hold supply current |
|
–4 |
|
4 |
mA |
IDR |
Output driver supply current |
|
–15 |
|
15 |
mA |
IE |
Digital encoder supply current |
|
–30 |
|
30 |
mA |
(1) Delta parameters are measured on the automated test equipment
(ATE) as part of the ATE program at both pre and post burn-in.
(2) The four delta parameter currents are measured at the beginning
of the ATE program. The voltage supply is then pulsed to the absolute max and
the remainder of the ATE program is executed. After the ATE program is executed,
the four delta parameter currents are measured again. The differences in the
measured supply currents at the beginning and end of the ATE program are the
delta parameters.
(3) Delta parameters are measured at TA = 25°C prior to
burn-in and at TA= –55°C, 25°C, and 125°C after burn-in. The
differences between supply currents measured before and after burn-in are not
included in the delta parameter analysis.
(4) For delta parameters outside of the distribution, the
corresponding parts are rejected.