SNAU288 December 2023 LMX1906-SP
To set LMX1906-SP to multiplier mode by using SPI, follow the steps below:
Set CLK_MUX (R25[2:0] = Multiplier (0x3).
Set CLK_MULT (R25[5:3]) to appropriate multiplier value for respective CLKIN frequency.
Press Calibrate Multiplier button in GUI.