Figure 1-1 shows default jumper configuration for the EVM.
To begin using the LMKDB1104EVM,
follow the steps below.
- Verify the EVM default jumper as
described in Table 3-1 and Figure 1-1.
- Change jumper JP10 from position 1-2 to position 2-3 to use USB
supply.
- Connect the USB cable to USB port
at J12.
- Connect 100MHz reference clock to CLKIN_P/N.
Refer to Table 4-8 for different input reference configurations.