Device Details

Table 1-1 lists the device information used in the initial TID characterization and qualification of HDR tests.

Table 1-1 Device and Exposure Details
TID HDR Details: 100 krad(Si)
TI Device Number TMP9R00-SP
Package 16-Pin HKT
Technology LBC8LV
Die Lot Number 1408182
AT Lot Number, Date Code 2002440
Quantity Tested 54units
Lot Accept, Reject Devices passed 100 krad(Si)
HDR Radiation Facility Texas Instruments SVA Group, Santa Clara, CA
HDR Dose Level 3krad(Si), 10 krad(Si), 30 krad(Si), 50 krad(Si), 75 krad(Si), 100 krad(Si)
HDR Dose Rate 60 rad(Si)/s
HDR Radiation Source Gammacell220 Excel (GC-220E) Co-60
Irradiation Temperature Ambient, room temperature