SNIS189D June   2015  – June 2018 LMT01

PRODUCTION DATA.  

  1. Features
  2. Applications
    1.     LMT01 Accuracy
  3. Description
    1.     2-Pin IC Temperature Sensor
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Electrical Characteristics
    6. 6.6  Electrical Characteristics - TO-92/LPG Pulse Count to Temperature LUT
    7. 6.7  Electrical Characteristics - WSON/DQX Pulse Count to Temperature LUT
    8. 6.8  Switching Characteristics
    9. 6.9  Timing Diagram
    10. 6.10 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Output Interface
      2. 7.3.2 Output Transfer Function
      3. 7.3.3 Current Output Conversion to Voltage
    4. 7.4 Device Functional Modes
  8. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Mounting, Temperature Conductivity, and Self-Heating
    2. 8.2 Typical Application
      1. 8.2.1 3.3-V System VDD MSP430 Interface - Using Comparator Input
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
          1. 8.2.1.2.1 Setting the MSP430 Threshold and Hysteresis
        3. 8.2.1.3 Application Curves
    3. 8.3 System Examples
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Receiving Notification of Documentation Updates
    2. 11.2 Community Resources
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Electrical Characteristics - WSON/DQX Pulse Count to Temperature LUT

Over operating free-air temperature range and 2.15 V ≤ VP – VN ≤ 5. 0 V power supply operating range (unless otherwise noted). LUT is short for Look-up Table.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Digital output code –50°C 15 26 37 pulses
–40°C 172 181 190
–30°C 328 337 346
–20°C 486 494 502
–10°C 643 651 659
0°C 800 808 816
10°C 958 966 974
20°C 1117 1125 1133
30°C 1276 1284 1292
40°C 1435 1443 1451
50°C 1594 1603 1611
60°C 1754 1762 1771
70°C 1915 1923 1931
80°C 2076 2084 2092
90°C 2237 2245 2254
100°C 2398 2407 2416
110°C 2560 2569 2578
120°C 2721 2731 2741
125°C 2802 2814 2826
130°C 2883 2894 2904
140°C 3047 3058 3068
150°C 3210 3221 3231