SNLA364C March   2021  – June 2022 DP83TD510E

 

  1.   Abstract
  2.   Trademarks
  3. Introduction
  4. 1-V and 2.4-V p2p Mode Scripts
  5. Time-Domain Reflectometry
    1. 3.1 TDR Application Startup
      1. 3.1.1 TDR_CFG (Address = 0x001E) [Reset = 0x0000]
      2. 3.1.2 TDR_Fault_Status (Address = 0x030C) [Reset = 0x0000]
    2. 3.2 TDR Test Procedure
  6. Active Link Cable Diagnostics
    1. 4.1 ALCD Application Startup
    2. 4.2 ALCD Test Procedure
      1. 4.2.1 Cable Calibration
      2. 4.2.2 Cable Quality Measurement
  7. Signal Quality Indicator
    1. 5.1 SQI Application Startup
      1. 5.1.1 MSE Detection (Address = 0x0A85 ) [Reset = 0x0000]
    2. 5.2 SQI Test Procedure
  8. Cable Diagnostics Summary
  9. Loopback Modes
    1. 7.1 BISCR (Address = 0x0016) [Reset = 0x0100]
  10. Pseudo-Random Bit Sequence Functions
    1. 8.1 PRBS_CFG_1 (Address = 0x0119) [Reset = 0x0574]
    2. 8.2 PRBS_STATUS_4 (Address = 0x011F) [Reset = 0x0000]
  11. USB to MDIO Procedure
  12. 10IEEE 802.3cg PMA Compliance
  13. 11Revision History

Cable Diagnostics Summary

With multiple cable diagnostic tools to choose from in the DP83TD510E, selecting the right tool for an application is important. The Table 6-1 offers information about when each tool can be used to detect faults and improve system performance.

Table 6-1 Cable Diagnostic Summary
Application Use Case Cable Diagnostic Tool
TDR ALCD SQI
Link Down Yes No No
Network Link Established No Yes Yes
Link segment length Yes Yes No
Open/Short detection Yes No No
Link quality monitor No No Yes