SNLA411 October 2022 DP83TC812R-Q1 , DP83TC812S-Q1 , DP83TC813R-Q1 , DP83TC813S-Q1
To wake-up the link partner remotely, the PHY needs to send a defined sequence of PAM3 symbols for 1 ms+/-0.3 ms. WUP transmission is done after a local wake-up without any manual intervention provided the device is strapped to autonomous mode and the pin RESET is not asserted. If the device is strapped to managed mode or if the device is in RESET state, WUP is transmitted only after the device transitions to normal mode.
During the sleep mode, to wake-up the PHY from sleep, remote link partner transmits WUP. The PHY detects the WUP and transitions from the sleep mode to functional mode. The core power supplies (VDDA, VDDIO/VDDMAC) are not needed for the PHY for WUP detection. The incoming WUP signal must be compliant to 100Base-T1 PMA signal PSD mask defined in IEEE802.3.