Test procedure used to obtain LMK6H's PCIe compliance report results is as follows:
- After powering up the device, the differential outputs are connected directly to an oscilloscope for time domain measurements, or to a PNA through a balun for frequency domain measurements.
- An output trace file is captured from the PNA or oscilloscope. Note that the oscilloscope capture requires both the positive and negative traces, so two output trace files from the oscilloscope are required.
- The files generated are run through TI's PCIe
Compliance Tool (Section 4 contains more information
about this tool).