SNLS507C September 2016 – December 2022 DS90UB934-Q1
PRODUCTION DATA
DS90UB934-Q1 supports the use cases shown in Table 5-1:
DS90UB934-Q1 DEVICE MODE | PCLK FREQUENCY RANGE | ||
---|---|---|---|
DS90UB913A-Q1 PARTNER | DS90UB933-Q1 PARTNER | DS90UB953-Q1/DS90UB935-Q1 PARTNER | |
RAW12 High-Frequency (HF) | 37.5 MHz - 75 MHz | 37.5 MHz - 100 MHz | 37.5 MHz - 100 MHz |
RAW12 Low-Frequency (LF) | 25 MHz - 50 MHz | N/A | N/A |
RAW10 | 50 MHz - 100 MHz | 50 MHz - 100 MHz | 50 MHz - 100 MHz |
The modes control the FPD-Link III receiver operation of the device. In each of the cases, the output format for the device is parallel.
The input mode of operation is controlled by the MODE strap pin. The input mode may also be overridden and configured by FPD3_MODE (Register 0x6D[1:0]) setting in the Port Configuration register.