SNLU226B February 2018 – April 2021 DS90UB960-Q1
A termination device is required to properly monitor and measure the transmission of the MIPI DPHY signals. The termination device must support the change of signals as it switches between LP and HS modes. This can be provided by either a CSI-2 receiver or a dedicated dynamic termination board. TI recommends the termination board is the UNH-IOL MIPI D-PHY Reference Termination Board (RTB).