External Supply

DP83825EVM provides the option to power individual voltage rails from external power source giving customers more flexibility with EVM testing. ‘VDD3V3’, ‘VDDIO’, and ‘MSP-IO’ connectors shown above are used to switch individual rails from LDO source to External source. Connect jumper between pin 2-3 to switch from LDO supply to External power source. Then supply power through corresponding pin on J8.

Note: Jumpers in Figure 2-5 are in position 1-2. For external use, switch to position 2-3.
GUID-20231207-SS0I-B4G0-QG87-FNBG5ZJ62JBF-low.svg Figure 2-5 Supply Selection - LDO

For example: If VDD3V3 needs to be supplied externally, then switch the jumper on VDD3V3 connector from position 1-2 to 2-3. Then supply 3.3V external power through pin 5 on J8.