SNOAA65 December 2020 TLV9022
To determine an appropriate overcurrent value, it is recommended to set the limit to roughly half of the battery usage rating or use the maximum discharge current rating of the battery. For this design, we are assuming a usage rating of 20Ah. This means we selected an overcurrent threshold of 10A. This approximately translates to two hours of battery life if the maximum current rating is maintained. A 10-mΩ resistor is used to sense the load current. This means that when a voltage of approximately 100mV is seen by the first channel of the TLV9022, the combined output of the channels will be pulled low. Using the resistive network in the previous image, where R1 and R2 are equal to 200kΩ and 6.25kΩ, respectively, will step the VTL voltage down from 3.29-V to approximately 100mV. This establishes the overcurrent threshold at 10A.