This report discusses the results of the total ionizing dose (TID) testing for the Texas Instruments TPS7H6013-SP radiation hardness-assured 1.3A, 2.5A, half-bridge gate driver. The study was done to determine TID effects at 100krad(Si) High Dose Rate (HDR). The results show that all samples pass within device specified test limits.