In this test example, a synchronous buck converter operation is implemented. The input voltage is 400 V, and the output voltage is 200 V with 50% duty cycle. With the heatsink-version EVM, the inductor current goes to 20 A in this test, and an output power of 4 kW is achieved. The waveform for continuous operation is shown in Figure 7-4 . The slew rate is set to 85 V/ns by connecting 20 kohm between Rdrv and ground. From this waveform, a turn-on voltage slew rate of 85 V/ns is observed at 400 V/20 A switching conditions.
The turn-on slew-rate of the device can be easily adjusted from 30V/ns to 150V/ns by changing the Rdrv resistor values. This is also verified from the test results shown in Figure 7-7. The adjustable slew-rate feature provides a flexibility to adapt the device's switching speed in different applications.