If there are issues with the PAMB
controller such that it is unable to connect to the GUI or the LEDs do not light, the
firmware may need to be re-flashed through a batch file.
Before this can be done, the PAMB
controller must be put back into Device Firmware Upgrade (DFU) mode. The steps to put
the controller into DFU mode are as follows:
- Ensure the USB cable is unplugged,
then remove the LDC3114 daughter card from the PAMB.
- Locate the two test points near the
PK1 and PK2 header pins.
- Reconnect the USB cable to power the
USB board.
- Use a pair of metal tweezers or wire
to short and hold the connection between the PK1 and PK2 test points.
- With the test points still shorted,
press and release the RESET button (SW1) on the PAMB board.
- If successful, none of the LEDS on
the PAMB board will be on.
- Launch the LDC3114EVM GUI.
- Navigate to File > Program
Device to launch the firmware update. Wait for the firmware to update and
do not disconnect the USB cable or press the RESET button during the
update.
- When the update is complete, the EVM
firmware should reboot and connect to the GUI. If the firmware does not reconnect
momentarily, press the RESET button OR unplug and plug in the USB cable to
reconnect.