SNVSCU2A August 2024 – August 2024 LM5137-Q1
ADVANCE INFORMATION
Program the LM5137-Q1 oscillator with a resistor from RT to AGND to set the free-running switching frequency between 100kHz and 2.2MHz. Calculate the RT resistance for a given switching frequency using Equation 2.