SNVU628 February 2020 LM5155 , LM5155-Q1 , LM51551 , LM51551-Q1
Power Supply: The input voltage source (VIN) should be an adjustable power supply capable of 0 V to 42 V and source at least 10 A.
Electronic Loads: The E-Load should be capable of at least 20 V and 5 A.
Multi-meters:
Oscilloscope: An oscilloscope and 10× probes with at least 20-MHz bandwidth is required. Measure the output voltage ripple directly across an output capacitor with a short ground lead. Do not use a long-lead ground connection due to the possibility of noise being coupled into the signal. To measure other waveforms, adjust the oscilloscope as needed.