SNVU760 February 2021
By default, the TPS3704Q1EVM does not support the RESET3 output. In order to use this EVM to evaluate RESET3 the TPS37044-Q1 option that is installed on the board must be replaced by a TPS37043-Q1 device. The TPS37043-Q1 device is capable of monitoring three voltage rails and outputing three active low reset signals. When evaluating this option, the following jumper configurations must be used:
Jumper J12 must be shunted in order to connect the RESET3 pin to the TP7 testpoint.
Jumper J11 must be placed in either the left or the right position in order for the RESET3 output to be pulled up to VDD or Vpu3 respectively.
Jumpers J4 and J8 must be left open.