SNVU767A
March 2022 – January 2024
1
LM63635DNEVM EVM User’s Guide
Trademarks
1
Setup
1.1
Jumpers
1.2
Test Points
2
Operation
3
Performance Curves
4
Schematic
5
Board Layout
6
Bill of Materials
7
Revision History
1.2
Test Points
VINEMI -
Input supply to EVM. Connect to an input supply.
GND -
System power ground.
VOUT -
Power output of EVM. Connect to desired load.
VOS -
Output voltage sense connection. Connect to DMM.
VINS -
Input voltage sense connection. Connect to DMM.
GNDS -
Ground sense point for analog measurements. Connect to DMM.
EN -
Connected to the EN input of the device.
RESET
-
Connected to the
RESET
pin of the IC. This is used as a flag output. The reset function can be monitored at this test point.
SYNC/MODE -
Input to SYNC/MODE pin. Note: Not all modes are available on all device options. Refer to the relevant data sheet for more details.
VCC -
Connected to the VCC output of the device. Can be used for logic level pullups, if needed.
OPEN PADS -
Connections for frequency response analyzer (on bottom of board) to take Bode plots. See
Figure 1-4
for details of connections.
Figure 1-4
FRA Setup