SNVU843A April   2023  – November 2023

 

  1.   1
  2.   LM5171 Evaluation Module
  3.   Trademarks
  4. 1Features and Electrical Performance
  5. 2Setup
    1. 2.1 EVM Configurations
    2. 2.2 Bench Setup
    3. 2.3 Test Equipment
    4. 2.4 Jumper Settings for Typical Operation Modes
      1. 2.4.1 Buck Mode with Voltage Regulation
      2. 2.4.2 Boost Mode with Voltage Regulation
      3. 2.4.3 Buck Mode with Current Regulation
      4. 2.4.4 Boost Mode with Current Regulation
      5. 2.4.5 2-EVM Daisy-Chain for 3 or 4-Phase Operation
  6. 3Test Procedure
    1. 3.1 Buck Mode Power-Up and Power-Down Sequence
    2. 3.2 Boost Mode Power-Up and Power-Down Sequence
    3. 3.3 Bidirectional Operation Power-Up and Power-Down Sequence
    4. 3.4 Operating the EVM With External MCU or Other Digital Circuit
  7. 4Test Data
    1. 4.1 Efficiency
    2. 4.2 Step Load Response
    3. 4.3 Dual-Channel Interleaving Operation
    4. 4.4 Typical Start Up and Shutdown
    5. 4.5 DEM and FPWM
    6. 4.6 Mode transition between DEM and FPWM
    7. 4.7 ISET Tracking
    8. 4.8 Pre-charge
    9. 4.9 Protections
  8. 5Design Files
    1. 5.1 Schematics
    2. 5.2 Bill of Materials
    3. 5.3 Board Layout
  9. 6Revision History

Buck Mode with Current Regulation

Figure 2-8 shows the jumper settings of buck mode with current regulation.

GUID-20230324-SS0I-KCQH-LD12-S2T3FC9GZSZR-low.svg Figure 2-6 Jumper Settings in Buck Mode with Current Regulation

Compared to Buck Mode with Voltage RegulationBuck Mode with Voltage RegulationBuck Mode with Voltage RegulationBuck Mode with Voltage Regulation, J36 is open and ISET is set from external precision voltage source . Also note the load needs to be set to CV mode.