SPRACP3C November 2019 – December 2021 AWR6843 , AWR6843AOP , IWR1443 , IWR1642 , IWR6443 , IWR6843 , IWR6843AOP
For the test setup a power meter is used to measure received power (Pr), the gain of the receiving antenna (Gr) is known, operating frequency and the distance of the receiving antenna to the EUT is measured. The unknown transmit power of the EUT TX chain is calculated using Friis equation, as in Equation 10.
where