SPRACP3C November 2019 – December 2021 AWR6843 , AWR6843AOP , IWR1443 , IWR1642 , IWR6443 , IWR6843 , IWR6843AOP
Problem Statement: Test results shows an overshoot or undershoot at the start of the chirp.
Solution: Increase the TX start time
ar1.ProfileConfig (0, 62.10, 2, 3.4, 18, 0, 0, 0, 0, 0, 0, 16.693, 1, 128, 10000, 0, 131072, 30))
The highlighted parameter above signifies TX start time of 1 µS.
Deep Dive:
TX start time indicates the time elapsed from the start of the frequency ramp to the time the transmitter is turned on. At the beginning of the ramp marked by ramp start in Figure 5-5 , the synthesizer, HPF analog filter, decimation filter, and so forth are switched on, and may require some settling time. If TX is turned on within the transient period it may result in overshoot or undershoot in the transmitted signal.