SPRACP3C November 2019 – December 2021 AWR6843 , AWR6843AOP , IWR1443 , IWR1642 , IWR6443 , IWR6843 , IWR6843AOP
The duty cycle factor is calculated as the duty cycle across bursts multiplied by the duty cycle within each burst.
Where X = Duty Cycle
BW Mode | On Time | Period | Duty Cycle | On time | Period | Duty cycle | Duty cycle Linear | Duty Cycle | Duty cycle correction |
---|---|---|---|---|---|---|---|---|---|
Between Burst | Within Burst | Total | |||||||
1300 | 4.29 | 16.06 | 0.267 | 29.66 | 33.33 | 0.890 | 0.24 | 23.76 | 6.24 |