SPRACV2 November 2020 AWR1843 , AWR2243
In Gen1 devices (AWR1243, AWR1843, AWR1642, AWR1443), TI recommends that the field “Enable LODIST calibration” in AWR RF INIT CALIBRATION CONF SB be set to 0 during customer factory calibrations for advanced single chip use cases where coherence across time and frames is desired. This keeps the configurations of the LO distribution buffers to the TX and RX sections constant (it is a measure to avoid abrupt phase jumps arising from their reconfigurations). As a result, the calibration report API messages (AWR AE RF INITCALIBSTATUS SB) will also report “LODIST calibration” status as 0.
In AWR2243, TI recommends that LO DIST calibrations are enabled while performing factory calibrations, i.e. the field “Enable LODIST calibration” in AWR RF INIT CALIBRATION CONF SB should be set to 1. The LO DIST calibration results are stored into NVM. During the field operation, the LO DIST calibration results are restored and LO DIST Temp Index can be forced (Low Bias, Mid Bias, and High Bias) to have corresponding LO DIST configurations.