SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
The noise filter is used to suppress any noise that is 50 ns or less in case of F/S operation modes, and any noise that is 10 ns or less in case of HS mode operation. The noise filter is always one period of the I2Ci_INTERNAL_CLK clock. This way, for HS mode operation (prescaler bypassed), the filter suppresses spikes of less than 10.4 ns.
For standard mode (for example, the I2Ci.I2C_PSC[7:0] PSC bit field = 4), the maximum width of suppressed spikes is 46.1 ns.
To ensure correct filtering, the prescaler must be programmed accordingly by the 2Ci.I2C_PSC[7:0] PSC bit field.