SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
Table 19-22 describes the events servicing in sending mode.
Step | Register/ Bit Field / Programming Model | Value |
---|---|---|
Read interrupt status bit | MAILBOX_IRQSTATUS_CLR_u[1 + m*2] | 0x1 |
Write message | MAILBOX_MESSAGE_m[31:0] MESSAGEVALUEMBM | 0x---- |
Write 1 to acknowledge interrupt | MAILBOX_IRQSTATUS_CLR_u[1 + m*2] | 0x1 |