SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
Table 3-176 lists the supported slave clock-management modes and associated software control bit fields for each module of the power domain.
Module | Disabled | Auto | Enabled | Control Bit Field | Access Type |
---|---|---|---|---|---|
AES1 | Available | Available | N/A | CM_L4SEC_AES1_CLKCTRL[1:0] MODULEMODE | Read/Write |
AES2 | Available | Available | N/A | CM_L4SEC_AES2_CLKCTRL[1:0] MODULEMODE | Read/Write |
SHA2MD5_1 | Available | Available | N/A | CM_L4SEC_SHA2MD51_CLKCTRL[1:0] MODULEMODE | Read/Write |
SHA2MD5_2 | Available | Available | N/A | CM_L4SEC_SHA2MD52_CLKCTRL[1:0] MODULEMODE | Read/Write |
DMA_CRYPTO | N/A | Available | N/A | CM_L4SEC_DMA_CRYPTO_CLKCTRL[1:0] MODULEMODE | Read only |
DES3DES | Available | Available | N/A | CM_L4SEC_DES3DES_CLKCTRL[1:0] MODULEMODE | Read/Write |
RNG | Available | Available | N/A | CM_L4SEC_RNG_CLKCTRL[1:0] MODULEMODE | Read/Write |
FPKA | Available | N/A | Available | CM_L4SEC_FPKA_CLKCTRL[1:0] MODULEMODE | Read/Write |