SPRUI30H November 2015 – May 2024 DRA745 , DRA746 , DRA750 , DRA756
Table 3-297 lists the static dependency of the clock domain with respect to other clock domains of the device.
Clock Domain Name | Default Setting | Control Bit Field | Access Type |
---|---|---|---|
CD_L3_MAIN1 | Always enabled | CM_VPE_STATICDEP[5] L3MAIN1_STATDEP | Read only |
CD_EMIF | Disabled | CM_VPE_STATICDEP[4] EMIF_STATDEP | Read/write |
CD_L4PER3 | Disabled | CM_VPE_STATICDEP[27] L4PER3_STATDEP | Read/write |