SPRUI33H November 2015 – June 2024 TMS320F280040-Q1 , TMS320F280040C-Q1 , TMS320F280041 , TMS320F280041-Q1 , TMS320F280041C , TMS320F280041C-Q1 , TMS320F280045 , TMS320F280048-Q1 , TMS320F280048C-Q1 , TMS320F280049 , TMS320F280049-Q1 , TMS320F280049C , TMS320F280049C-Q1
The data rate of the sinc filter (filter throughput) represented in samples/sec is calculated by the following formula:
The latency of the sinc filter represented in secs is defined as the amount of time taken by a sinc filter type to deliver the correct filtered output upon initiation. For a given filter type, latency is calculated by the following formula:
Example configuration:
Sinc filter type | = sinc3 |
Modulator data rate | = 10MHz |
OSR | = 256 |
Data rate of Sinc Filter | = 10MHz/256 = 39.1K samples/second |
Sinc filter latency | = 76.8µs |
Sinc filter type | = sinc2 |
Modulator data rate | = 10MHz |
OSR | = 256 |
Data rate of Sinc Filter | = 10MHz/256 = 39.1K samples/second |
Sinc filter latency | =51.2µs |