SPRUI78D March 2019 – January 2022 TMS320F28075 , TMS320F28075-Q1 , TMS320F28076 , TMS320F28374D , TMS320F28374S , TMS320F28375D , TMS320F28375S , TMS320F28375S-Q1 , TMS320F28376D , TMS320F28376S , TMS320F28377D , TMS320F28377D-Q1 , TMS320F28377S , TMS320F28377S-Q1 , TMS320F28378D , TMS320F28378S , TMS320F28379D , TMS320F28379D-Q1 , TMS320F28379S
To stay as general as possible, the safety concept assumes the MCU playing the role of a processing unit (or part of it) and connected to remote controller(s) by means of a communication bus as shown in Figure 4-1. The communication bus is directly or indirectly connected to sensor(s) and actuator(s). (Reference: Yogitech Initial Safety Analysis Report - YT_D3).
IEC 61508:1 clause 8.2.12 defines a compliant item as any item (for example an element) on which a claim is being made with respect to the clauses of IEC 61508 series. A system including TMS320F2837xD/S or TMS320F2807x microcontroller as indicated by Figure 4-1 can be used in a compliant item according to IEC 61508.