SPRUI78D March 2019 – January 2022 TMS320F28075 , TMS320F28075-Q1 , TMS320F28076 , TMS320F28374D , TMS320F28374S , TMS320F28375D , TMS320F28375S , TMS320F28375S-Q1 , TMS320F28376D , TMS320F28376S , TMS320F28377D , TMS320F28377D-Q1 , TMS320F28377S , TMS320F28377S-Q1 , TMS320F28378D , TMS320F28378S , TMS320F28379D , TMS320F28379D-Q1 , TMS320F28379S
The start of conversion (SOC) signal input to the ADC module can be triggered by multiple sources, mainly Software, CPU Timers, GPIO, and PWM module instances. In order to achieve freedom from interference due to a fault originating from an peripheral not used in implementing the safety function and cascading into ADC, it is recommended that application configures only the requires SOC triggers. This is a way to avoid faults originating from an outside source to impact functionality of ADC.