SPRUID8D September 2020 – January 2022 TMS320F280040-Q1 , TMS320F280040C-Q1 , TMS320F280041 , TMS320F280041-Q1 , TMS320F280041C , TMS320F280041C-Q1 , TMS320F280045 , TMS320F280048-Q1 , TMS320F280048C-Q1 , TMS320F280049 , TMS320F280049-Q1 , TMS320F280049C , TMS320F280049C-Q1
The ePWM outputs can be monitored for proper operation by an input capture peripheral, such as the eCAP. The connection between ePWM output and eCAP input can be made either externally in the board or internally using X-BAR. Error response, diagnostic testability, and any necessary software requirements are defined by the software implemented by the system integrator. Similarly eCAP can be tested by measuring ePWM pulse width as a test for diagnostic. XINTxCTR (counter of XINT module), capture mode of eQEP and DCCAP (PWM event filter unit) can also be used to detect rising/falling edges of the PWM and extract the timestamping information. This information can be further used to build additional diagnostics.