The diagnostics library designed for the F28002x family of devices is Software Diagnostic Library
(SDL). This library is designed to help TI customers, using the F28002x, develop functionally safe systems that can comply with a wide range of
standards for end products in the appliance (IEC 60730) market. The SDL provides examples for several safety mechanisms provided in the safety
manual.
Table 4-1 F28002x Diagnostic Library details
Library |
Permanent Fault Diagnostic Coverage |
Systematic Capability Compliance |
Description |
SDL |
Examples Only |
N/A |
The SDL provides examples of several safety mechanisms described in the safety
manual |
The SDL is an integral part of the overall safety related collateral provided by TI. The SDL examples are developed using a Baseline Quality
software development flow and are not required to be compliant with any particular standard. As such, the SDL is not certified. Users are expected
to study and adapt the provided examples into their safety related applications and are responsible to for their own product level third party
certifications. The SDL is a collection of library modules and examples intended to demonstrate implementations of several of the software
diagnostics and software tests of diagnostics described in this document. Additionally, the SDL and accompanying Compliance Support Package (CSP) is
provided to assist customers develop systems that address requirements of IEC 60730, IEC 60335, ISO 26262 and IEC 61508 and other functional safety
standards. The SDL is available in
C2000Ware under
/libraries/diagnostic.