- MMCSD0_CLOCK_CONTROL[15:8].SDCLK_FRQSEL should be set to 200 MHz.
- PHY’s DLL should be enabled.
- MMCSD0_SS_PHY_CTRL_6_REG[27:24].BISTMODE should be set to 4’b0010.
- MMCSD0_SS_PHY_CTRL_6_REG[31].BISTENABLE should be set to 1’b1.
- MMCSD0_SS_PHY_CTRL_4_REG[20].OTAPDLYENA to 1’b1.
- MMCSD0_SS_PHY_CTRL_4_REG[15:12].OTAPDLYSEL to one of the tap values based on
Timing Closure.
- MMCSD0_SS_PHY_CTRL_4_REG[8].ITAPDLYENA to 1’b0
- MMCSD0_SS_PHY_CTRL_4_REG[4:0].ITAPDLYSEL to 5’b00000
- MMCSD0_SS_PHY_CTRL_4_REG[9].ITAPCHGWIN to 1’b0
- MMCSD0_SS_PHY_CTRL_5_REG[10:8].FRQSEL should be set for 200 MHz Mode.
- MMCSD0_SS_PHY_CTRL_4_REG[31:24].STRBSEL should be set to appropriate values
based on based on STRB timing closure.
* If Timing closure requires usage of Input Tap Enable and Tap Select should be set
appropriately.