SPRUJ40C may 2022 – may 2023
Applicable EVM Revisions: E1, E2
Issue Description: RGMII1 and RGMII2 PHYs (U51and U49) had strapping resistors for Tx Clock Skew = 2ns. Tx Clock skew should be set to 0ns as AM62x MAC always has internal delay enabled for Tx. Rx Clock Skew should remain 2ns.