SPRZ455D december 2020 – june 2023 DRA829J , DRA829J-Q1 , DRA829V , DRA829V-Q1 , TDA4VM , TDA4VM-Q1
ADVANCE INFORMATION
CPTS: GENF (and ESTF) Reconfiguration Issue
Re-configuring a GENF/ESTF function after having been previously configured has an issue. Issue details:
If GENF re-configuration occurs when the GENF output is logic one then the re-configuration comparison time will be a half-count instead of the full count, and the GENF output will be off by 1/2 cycle. The re-configured cycle will be correct if the GENF output is logic zero when the re-configuration occurs.
GENF reconfiguration can only happen after a SOC hardware reset.