SPRZ466C March 2020 – February 2024 TMS320F280021 , TMS320F280021-Q1 , TMS320F280023 , TMS320F280023-Q1 , TMS320F280023C , TMS320F280025 , TMS320F280025-Q1 , TMS320F280025C , TMS320F280025C-Q1
ePWM: Event Latch (DCxEVTxLAT) of "DC Event-Based CBC Trip" May not Extend Trigger Pulse as Expected When Asynchronous Path is Selected
0
DCxEVTxLAT may lose the captured trigger event for an asynchronous input upon deassertion. When an asynchronous trigger is deasserted, it is expected that the flop holds the value until there is a Clear event. Since the trigger is asynchronous with respect to the clock of the flop, there is a possibility that the flop may get cleared during deassertion. This would result in a loss of event latch function.
None