John Betten
High-voltage capacitive energy storage often provides power to repetitive high-power pulse loads such as a camera flash or radio transmitter. Storage capacitors supply a brief, high-power burst of energy to the load, but are then allowed to slowly recharge over a much longer time period. Their benefits generally include a lower average input current, which eases the requirements on the input source and reduces the size of the converter’s power stage. But storage capacitors can be quite large, so it’s beneficial to accurately determine the capacitance necessary in order to minimize their size. Let’s take a look at how to determine the required amount of capacitance.
The load discharging the storage capacitors can be categorized into three types: constant power, constant current or resistive. Figure 1 shows an example of how each type discharges a stand-alone 3400µF capacitor charged to 32V with an initial load of 69W. The constant power load, equivalent to that of a switching regulator, increases its current draw as the capacitor voltage decreases, further accelerating the voltage decay. To make things worse, the switching regulator’s efficiency also has an impact on the discharge rate. Converters such as boosts generally have lower efficiency as their input voltage decreases, drawing even higher power. Constant power is the most severe of the three types, requiring the most capacitance.
A constant current load provides a linear discharge slope. This makes predicting the capacitor’s “end” voltage relatively easy. The power drawn from the storage capacitor decreases as its voltage decreases and only certain types of loads have these characteristics. Examples of constant current loads include integrated circuits or applications such as a constant current LED driver, whose current is regulated by a linear regulator.
A resistive load has an exponentially decaying voltage and the longest holdup. A resistive load type is the least common of the three. Examples include an incandescent bulb, heating element or active load.
Once you know the load type, you can
use Equations 1, 2 and 3 to determine the necessary storage capacitance for a given
holdup time. Based on the curve in Figure 1, a constant-power load such as a 12V buck regulator could
operate for about 21ms before falling out of regulation. Alternatively, a constant
current load could support at least 16V for 25mS before requiring a recharge. If you
require a regulator to supply a fixed output voltage, be sure to factor in its
efficiency, as it will shorten the holdup time. Equations 1, 2 and 3 are:
where
Energy storage with a repetitive pulse load requires an understanding of the load type and its impact on the storage capacitor discharge rate. This allows you to select the proper capacitor bank size to achieve the necessary timing. High-voltage capacitive storage provides an effective method to supply a large, short-duration energy pulse.
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS” AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource. Other reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (www.ti.com/legal/termsofsale.html) or other applicable terms available either on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable warranties or warranty disclaimers for TI products.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2023, Texas Instruments Incorporated