The AON domain contains circuitry that is always enabled, except for the shutdown mode (where the digital supply is off). This domain includes the following:
- The RTC can be used to wake the CC13x2 and CC26x2 device platform from any
state where it is active. The RTC contains three match registers and one compare
register. With software support, the RTC can be used for clock and calendar
operation. The RTC is clocked from the 32 kHz RC oscillator or the
32 kHz crystal oscillator. - The battery monitor and temperature sensors are accessible by software. The battery monitor and temperature sensors provide continuous monitoring of battery state as well as coarse temperature.