SWCU191 February 2022 CC1311P3 , CC1311R3 , CC2651P3 , CC2651R3 , CC2651R3SIPA
In this scenario the user:
Figure 20-10 shows the scenario when N = 2, which ignores 1 stop event.
Table 20-13 lists the associated timing requirements for this scenario.
Description | Label | Requirement |
---|---|---|
Minimum high time, start | t_minH_start | 42 ns |
Minimum low time, start | t_minL_start | 126 ns |
Minimum high time, stop | t_minH_stop | 42 ns |
Minimum low time, stop | t_minL_Stop | 168 ns |
Minimum stop event period | t_min | 210 ns |
Minimum delay | TRIGCNTLOAD > 0 | t_d | 168 ns |
Minimum delay | TRIGCNTLOAD = 0 | t_d | 292 ns |