SWCU191 February 2022 CC1311P3 , CC1311R3 , CC2651P3 , CC2651R3 , CC2651R3SIPA
There are up to 32 signals (AUXIO0 to AUXIO31) in the AUX Domain. These signals can be routed to specific DIO pins given in Table 14-2. The signals AUXIO19 to AUXIO26 have analog capability, but can also be used as digital I/Os. All the other AUXIOn signals are digital only. The signals routed from the AUX Domain are configured differently than GPIO and other peripheral functions. This section does not cover the use of all the capabilities of the AUX Domain (for more details, see Chapter 19).
In this example, AUXIO1 is mapped to DIO17 and set up as a digital input.