SWRA737A February   2022  – August 2022 CC1352P , CC1352R , CC2640R2F , CC2640R2L , CC2642R , CC2652P , CC2652R , CC2652R7 , CC2652RSIP

 

  1.   Abstract
  2.   Trademarks
  3. 1Introduction
    1. 1.1 Acronyms
  4. 2Verify RF Performance With SmartRF Studio
  5. 3Verify RF Performance With BTool
    1. 3.1 BTool Basic Operation
    2. 3.2 Perform Tx Test
    3. 3.3 Perform Rx Test
    4. 3.4 Perform Reading RSSI
    5. 3.5 Perform PER Test
    6. 3.6 Notes for Different PHY Rate
      1. 3.6.1 Test logs for 2Mbps
      2. 3.6.2 Test logs for 500Kbps
      3. 3.6.3 Test logs for 125Kbps
    7. 3.7 The Difference Between HCI_EXT_ModemTestTxCmd and HCI_LE_Transmitter_Test
  6. 4Summary
  7. 5References
  8. 6Revision History

Notes for Different PHY Rate

To run the PER test on different PHY’s, the sequence of commands are different from the above section in the following ways:

In step 1 of Section 3.5 on Rx side, send the device a HCI_LE_EnhancedReceiverTest command instead of the HCI_LE_ReceiverTest command.

GUID-20220224-SS0I-SFMC-J5XV-B6LFZPKBZX42-low.png Figure 3-11 Set HCI_LE_EnhancedReceiverTest

In step 3 of Section 3.5 on Rx side, send the device a HCI_LE_EnhancedTransmitterTest command instead of the HCI_LE_TransmitterTest command.

GUID-20220223-SS0I-PSCW-DTCW-C65X9MNR10KV-low.png Figure 3-12 Set HCI_LE_EnhancedTransmitterTest
GUID-20220224-SS0I-GFR0-VJMV-HPDPRFCGKV0T-low.png Figure 3-13 Response After Setting HCI_LE_EnhancedTransmitterTest

Below lists the test logs for different PHY rate.