ADC_01

Periodic ADC trigger at 200 kHz rate can be ignored when XOSC_HF is turned on or off

Revisions Affected:

Revision E and earlier

Details:

There is no dedicated clock source selection for the ADC clock. The clock is derived from either XOSC_HF or RCOSC_HF, but defaults to XOSC_HF-derived clock whenever this is turned on.

When the ADC clock source is switched from RCOSC_HF to XOSC_HF-derived clock, the clock will stop for 2 cycles (24 MHz).

When the ADC clock source is switched from XOSC_HF-derived clock to RCOSC_HF-derived clock, the clock will stop for additionally 12 clock cycles, as the RCOSC_HF-derived clock is not ready when switch is done.

The fact that the clock is stopped, together with the difference in frequency between XOSC_HF and RCOSC_HF, may cause the ADC sampling and conversion to finish too late to catch the next trigger.

Workaround 1:

Use asynchronous sampling.

The sampling period after the issue occurs can be reduced by up to 20% (12 + 1 clock cycles at 24 MHz)

To use the ADC in asynchronous mode from the Sensor Controller:

Call adcEnableAsync() to enable the ADC, instead of adcEnableSync()

Example:

adcEnableAsync(ADC_REF_FIXED, ADC_TRIGGER_AUX_TIMER0);

To use the ADC in asynchronous mode from the System CPU, by using the ADCBuf driver:

ADCBuf_Params params;
ADCBufCC26X2_ParamsExtension paramsExtension;

ADCBuf_Params_init(&params);
ADCBufCC26X2_ParamsExtension_init(&paramsExtension);

paramsExtension.samplingMode = ADCBufCC26X2_SAMPING_MODE_ASYNCHRONOUS;
params.custom = &paramsExtension;

To use the ADC in asynchronous mode from the System CPU, by using DriverLib API:

Call AUXADCEnableAsync()to enable the ADC, instead of AUXADCEnableSync()

Example:

AUXADCEnableAsync(AUXADC_REF_FIXED, AUXADC_TRIGGER_GPT0A);

Please note the difference between the asynchronous and synchronous ADC modes:

  • In asynchronous mode, the ADC trigger ends the sampling period (which started immediately after the previous conversion), and starts conversion.
  • In synchronous mode, the ADC trigger starts the sampling period (with configurable duration), followed by conversion.

Workaround 2:

Ensure that XOSC_HF is not turned on or off while the ADC is used.

Workaround 3:

Increase the sampling period by (12+1)/24 µs or more.