SWRZ080D january 2018 – june 2023 CC2652R
Elevated power-on-reset (POR) threshold voltage at low operating temperatures.
Revision F and earlier
When powering up the device from 0 V at below 0 °C, the POR circuit might not release reset before VDDS has reached 2.3 V instead of 1.8 V. After POR has released the reset, an affected device can continue to operate at voltages down to 1.8 V.
Workaround 1: Power-up the device at VDDS > 2.3V when operating at temperatures below 0°C.
or
Workaround 2: Power-up the device at VDDS < 2.3V AND trigger the Reset pin from a host MCU or external circuitry once VDDS reaches 1.8V.
In addition, when operating the device in external regulator mode, workaround 2 must be implemented. Please note that VDDS must not exceed 1.95V in external regulator mode. This is applicable only to devices that have external regulator mode support.