TIDA035 October 2020
This addendum presents an approach to adapt the existing reference design TIDA-01513 to calculate the exact insulation resistances for two-point leakage errors. It is a necessary feature as dictated in many International Standards. This is applicable in HEVs and EVs as battery management systems, traction inverters, DC/DC converters, onboard chargers, and other subsystems operate at high voltage (higher than 60 V). The insulation resistance measurement error is caused by many factors such as resistance tolerance, op-amp non-ideal performance error, and ADC tolerance. The complete error analysis is beyond the scope of this document. However, the effect of the op-amp non-idealities on the measured insulation resistance is presented, and can serve as a starting point for further analysis.