This section describes the jumpers:
- Low (R15) is the low-level
adjustment of the load transient. Turning the potentiometer clockwise raises
the low level.
- High (R23) is the
high-level adjustment of the load transient. Turning the potentiometer clockwise
raises the high level.
- Pos Slew (R12) is the
positive slew rate adjustment. Turning the potentiometer clockwise increases
the rising transition time.
- Neg Slew (R58) is the
negative slew rate adjustment. Turning the potentiometer clockwise increases
the falling transition time.
- Settling (R43) is the
settling time adjust. Turning the potentiometer clockwise dampens the
oscillations by increasing the time required for the transition to settle to a
steady state value.
- Width (R47) is the pulse
width adjustment of the high level. Turning the potentiometer clockwise
increases the pulse width.
- Delay (R46) is the delay
adjustment of the high level relative to the period. Turning the potentiometer
clockwise increases the delay time.
- Period (R36) is the period
adjustment of the low level. Turning the potentiometer clockwise increases the
period.