TIDT317 March 2023
The conducted emissions are tested to the CISPR 25 class 5 standards. The CISPR 25 class-5 compliance was achieved without a common-mode choke. The waveforms of EMI test results are shown in following pictures.
The following images illustrate the
EMI performance from 150 kHz to 108 MHz. Additionally, in every image:
Line 1: CISPR 25 Class 5 peak limits; Line 2: CISPR 25
Class 5 average limits;
Line 3: Peak detection result;
Line 4: Average detection result.
The margin of each EMI test result is shown in the following table.
VIN (V) | VOUT (V) | Measurement Line | Margin (dB) |
---|---|---|---|
13.5 | 5 | Positive line | 13.1 |
13.5 | 5 | Negative line | 13.1 |
13.5 | 9 | Positive line | 8.7 |
13.5 | 9 | Negative line | 8.5 |
13.5 | 15 | Positive line | 6.6 |
13.5 | 15 | Negative line | 6.6 |
13.5 | 20 | Positive line | 8.6 |
13.5 | 20 | Negative line | 8.6 |