TIDT358 May   2024

 

  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Dimensions
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
  7. 3Waveforms
    1. 3.1 Switching
    2. 3.2 Output Voltage Ripple
    3. 3.3 Load Transients
    4. 3.4 Start-Up Sequence

Load Transients

Load transient response is shown in the following figures.

PMP23431 Load Transient 1: 60VIN,
                        33VOUT, 10mAOUTFigure 3-5 Load Transient 1: 60VIN, 33VOUT, 10mAOUT
PMP23431 Load Transient 2: 800VIN,
                        33VOUT, 30mAOUT to 100mAOUTFigure 3-6 Load Transient 2: 800VIN, 33VOUT, 30mAOUT to 100mAOUT
PMP23431 Load Transient 3: 1000VIN, 33VOUT, 30mAOUT
                    to 100mAOUT Figure 3-7 Load Transient 3: 1000VIN, 33VOUT, 30mAOUT to 100mAOUT